I'm helping a guy out with an IBM X 3550 server, Raid 5 setup (3 by 1 HS) on a M1115 (I think) raid card by LSI. Win 2008r2 acting as DC and file server.
Server has been crashing constantly, 4-9 times a day. All crashes appear to only happen during the day when users are using it. 99% of the crashes happen at the top of the hour. The crashes are hard, no Dump file is written. All access to the storage is shutdown.
Crashes are:
Kernel_Data_Inpage_Error Stop 7A
or
Stop: 0x000000F4
The IBM Storage Management software is reporting:
ID = 15
SEQUENCE NUMBER = 345
TIME = 13-03-2015 09:01:08
LOCALIZED MESSAGE = Controller ID: 0 Fatal firmware error: Line 5507 in ../../raid/raidpci.c
ID = 15
SEQUENCE NUMBER = 344
TIME = 13-03-2015 09:01:08
LOCALIZED MESSAGE = Controller ID: 0 Fatal firmware error: Line 5507 in ../../raid/raidpci.c
IBM has replaced the...